FCI ST50/ST51 Gas flow measurement

FCI flow meters for gases (gas mass flow meters) use the thermal dispersion measuring technique. Two pins (thermo elements) are immersed in the medium to be measured. One pin, the active temperature sensor (PT1000) is heated, the other PT1000 measures the temperature. The passing medium causes a cooling effect, which is measured as a temperature difference (Delta T) and calculated in the device. This measuring system does not require a measuring computer or additional sensors. A single process connection is sufficient. The sensors are designed to be extremely robust and durable.

ST 50: for air (compressed air) and nitrogen

ST 51: for biogas, digester gas, landfill gas, methane and natural gas

FCI ST50/ST51 Gas-Durchfluss-Messung
FCI ST50/ST51 Gas flow measurement
ST50/ST51 – Technical data:
for gases
Process connection: 1/2" NPT or 3/4" NPT female thread
Insertion length: 51 mm to 610 mm (adjustable on site)
Medium temperature: 18° C to 121° C (177° C)
Operating pressure: max 34 bar
Turndown ratio: up to 100:1
Communication: 4-20 mA / RS232C
Optional 0-500 Hz pulse output
Easily removable with additional ball valve

ST51 only - Technical data:
ATEX zone 1
4-20 mA according to NAMUR NE43

Optional – Technical data:
HART / Modbus / SIL

FCI ST75 Gas flow measurement (inline)

FCI flow meters for gases (gas mass flow meters) use the thermal dispersion measuring technique. Two pins (thermo elements) are immersed in the medium to be measured. One pin, the active temperature sensor (PT1000) is heated, the other PT1000 measures the temperature. The passing medium causes a cooling effect, which is measured as a temperature difference (Delta T) and calculated in the device. This measuring system does not require a measuring computer or additional sensors. A single process connection is sufficient. Due to their design, the sensors are extremely robust and durable.

FCI ST75 Gas-Durchfluss-Messung (Inline)
FCI ST75 Gas flow measurement (inline)
Technical data:
all types of Gases
for small pipe diameters 1/4 to 2 inch (inline)
Process connection: NPT male thread, NPT female thread, flange
Medium temperature: 18° C to 121° C
Operating pressure: 16.5 bar (max 41 bar)
Turndown ratio: up to 100:1
Output: 2x 4-20 mA according to NAMUR NE43
Pulse output: 0-500 Hz
ATEX zone 1
Optional – Technical data:
HART / Modbus / SIL

FCI ST80/ST100 gas flow measurement with adaptive sensor technology

FCI flow meters for gases (gas mass flow meters) use thermal dispersion measurement technology. (For more information on the measuring principle, see ST50/51) This means that a single process connection is sufficient. Due to their design, the sensors are extremely robust and durable.

The ST80 and ST100 sensors can be equipped with different sensor heads (also for wet gases). They have 4-20 mA outputs in accordance with NAMUR, all bus communications and are SIL 1 approved. The clear display shows the measured values graphically and digitally. The sensors are suitable for pipes up to 2500 mm in diameter. Larger pipe diameters are equipped with up to 3 sensors.

ST 80 and ST 100:
Gases of all types
Process connection: NPT thread, flange, packing gland
Installation length: 25 mm to 1524 mm adjustable on site
Medium temperature: max 454° C
Turndown ratio: up to 100:1
Response time: 1 sec.
Accuracy: ± 1.0 % of the measured value, ± 0.5 % of the full scale value
3-point calibration drift test on site
ATEX zone 1
remote electronic possible (300 m) - optional
Inline L version for small pipe diameters of 1 and 2 inches
ST100 only:
Accuracy: ± 0.75 % display, ± 0.5 % of full scale value
Pulse or frequency output (0-1 kHz / 0-10 kHz)
5 different gas calibrations can be stored
Ethernet compatible
Built-in data logger